iFuse Trauma™ | SI-BONE

Trauma

Trauma poster

Do Your High Energy Pelvic Trauma Patients Have Ongoing Pain?

  • Patient outcomes after traumatic disruption of the SI joint are directly correlated to the quality of SI reduction.85,86,87
  • Up to 85% of SI trauma patients develop SI joint pain and poor function due to post-traumatic arthritis or malreduction.88,89,90,91,92,93,94,95,96
Incidence of Residual SI Joint Pain in Pelvic Trauma Patients. Up to 85% of SI trauma patients develop SI joint pain and poor function due to post-traumatic arthritis or malreduction.

Do You Treat Low Energy Sacral Fractures Surgically?

Complications with nonsurgical management:

  • 14-45 day average hospital stay.97,98,99
  • 29-61% risk of thromboembolic disorder.100,101
  • 14-27% mortaility rate at one year.97,98

Complications with alternative surgical treatment: 

  • 20% risk of iliosacral screw backout.102
  • 32% risk of extravasation in sacroplasty procedures.103
Type B Sacral Fractures
Type B Sacral Fractures
Case Studies

The iFuse Trauma Technique

The iFuse 3D™ Implant

Fix
  • Triangular implant geometry provides immediate stabilization.
  • Unique design provides press fit fixation between the implant and adjacent osseous walls.
  • 31x greater rotational resistance vs. 7.3mm screw.82
Fuse
  • 3D printed implant with porous surface facilitates bone ongrowth.17
  • Fenestrated structure allows for bone through growth and accommodates bone graft.17
  • Porous surface self harvests bone during insertion.17
Fortify
  • Rigid titanium construction provides an implant that is 18x stronger than the worst-case physiologic load, thus fortifying the SI joint.83
  • More than 5x fewer revisions after fusion with iFuse vs. iliosacral screws.81

Learn More About iFuse 3D

iFuse-3D™  Implant
iFuse-3D™ Implant

Clinical Brief

  1. Retrospective, multicenter review of 50 patients with high and low energy pelvic trauma treated with the iFuse Implant System® in adjunct to traditional hardware fixation
  2. Average decrease in Visual Analog Scale (VAS) pain score from 8.9 at time of fracture to 1.9 at last follow-up
  3. On average, functional mobility was restored to pre-fracture status

Learn

SI Joint and iFuse Implant System Training

SI-BONE offers training on SI joint diagnosis and treatment for healthcare providers. Learn more about SI joint training opportunities.

Find Out More

3,600+Treating Surgeons

95,000+iFuse Procedures Performed

125+iFuse Publications

Looking for Answers?

We can help. Tell us what you're looking for below.